An evaluating technique for variety compatibility of fruit applied to a near infrared
Brix calibration system: a case study using Brix calibration for nectarines Giorgio Reita,a Cristiana Peano,a Sirinnapa
Saranwongb and Sumio Kawanob,* aDepartment of Arboricolture and Pomology, University of Turin, Via Leonardo da Vinci 44,
Grugliasco (TO), Italy bNational Food Research Institute, 2-1-12 Kannondai, Tsukuba 305-8642, Japan. E-mail: kawano@affrc.go.jp
ABSTRACT:
In a practical near
infrared (NIR) sweetness sorting facility, there is a high possibility that the variety of incoming fruit will be different from the one(s) used to develop a calibration model. In this kind
of situation, significant bias could occur and result in a high price difference. In this work, a method to identify whether the pre-installed calibration models could be used to predict
Brix values of the unknown samples or not was established. Two kinds of calibration model for Brix determination of nectarines were examined, one developed from spectra of the
single nectarine variety called Big Bang Maillarą (BB), the other developed from spectra of two nectarine varieties, BB and Nectaross (NT). Another variety called Sweet Red (SR)
was used to demonstrate the situation of an unknown sample or a different variety. For the general biases evaluation, significant biases occurred in the SR samples whether the
prediction was done using the BB calibration (bias = –6.74°Brix) or the BB+NT calibration (bias = –3.09°Brix). A survey using score plots of
principle component analysis (PCA) indicated that the characteristics of the BB and the SR samples were quite different from each other, while the NT samples were located in
between. Even though the trend of differences between the PCA scores of the three varieties could be observed, a clear classification result could not be obtained. Another
classification attempt was made using soft independent model for classification analogy (SIMCA). For each calibration (BB and BB+NT), a SIMCA model was developed using the
samples used to develop the calibration model. A calculation was performed to evaluate whether the unknown samples (BB, NT and SR) were in the same class as the calibration
sample or not. It was found that, in the case of the single variety calibration where the SIMCA model was also developed from the single variety (BB), clear identification of unfitted
samples could be obtained with classification accuracy more than 95% (false negative 0%). However, in the case of the two varieties calibration, the use of a SIMCA box developed
from two varieties would make the in-class distance become too wide and this reduced the classification accuracy of unfitted samples (false negatives = 74%). The solution was to
develop two SIMCA boxes, one for BB and one for NT, then examine the compatibility of unknown samples twice. Using this technique, satisfactory classification results with false
negatives of 10% could be obtained.
Keywords: near infrared (NIR) spectroscopy, non-destructive techniques, SIMCA, chemometrics, identification, calibration model, nectarine, variety,
Brix value
|