Abstract

Journal of Near Infrared Spectroscopy
Volume 17 Issue 5, Pages 255–264 (2009)
doi: 10.1255/jnirs.853

Quantitative analysis of DL-lactic acid and acetic acid in Kefir using near infrared reflectance spectroscopy

Armelle L. Ntsame Affane,a Glen P. Fox,a,b Gunnar O. Sigge,a Marena Manleya and Trevor J. Britza,*
aDepartment of Food Science, University of Stellenbosch, Private Bag X1, Matieland (Stellenbosch) 7602, South Africa. E-mail: tjbritz@sun.ac.za
bDepartment of Employment, Economic Development & Innovation, Queensland Primary Industries and Fisheries, PO Box 2282, Toowoomba, Queensland 4350, Australia

To be able to monitor in real time the concentrations of DL-lactic acid and acetic acid present in Kefir, a self- carbonated fermented milk product, near infrared (NIR) calibration models were constructed based on NIR spectra of 174 samples. Enzymatic tests and gas liquid chromatography were the reference methods used for DL-lactic acid and acetic acid, respectively. The fit of the models and their prediction power were evaluated using segmented cross-validation and an external validation set. The models obtained for DL-lactic acid were found to be acceptable for both cross-validation (R2 = 0.90, SECV = 0.110 g 100 mL–1 and RPD = 3.16) and external validation (r2 = 0.87, SEP = 0.156 g 100 mL–1 and RPD = 2.57). In contrast, the models for acetic acid were found to be unacceptable. The results obtained for both cross-validation (R2 = 0.80, SECV = 0.013 g 100 mL–1 and RPD = 2.21) and external validation (r2 = 0.44; SEP = 0.017 g 100 mL–1 and RPD = 1.17) suggested this model requires further development. The application of principal component analysis (PCA) to the entire sample set showed Kefir prepared with laboratory Kefir grains (LG), traditional Kefir grains (TG) and mass cultured Kefir grains (MG) resulted in similar PCA score values in spite of the Kefir grains not having the same origin. PCA was also able to differentiate between fermented and “milky body-like” samples. The findings of this study could serve the dairy industry in monitoring more efficiently the acidity in terms of DL-lactic acid of fermented dairy products.

Keywords: Kefir grains, fermented milk products, quantification, principal component analysis (PCA), partial least squares (PLS)


Full-text article (2091 kB) (subscribers only)

Buy article on-line for £20 (get immediate access)

Alerting Service

 RSS Feed

Permalink: http://dx.doi.org/10.1255/jnirs.853
QR Code (what is this?):


Alerting Services

Our Table of Contents Alerting Service will keep you up-to-date with the latest research published in our journals.

You can also follow our journals on Twitter or subscribe to their RSS feeds.  Follow us on Twitter and Subscribe to our RSS Feeds

Sign Up Now

Subscriptions

Discover the benefits of subscribing to our periodicals

  • Quality Science
  • Fair Pricing
  • Important Research
  • Flexible Subscriptions

Subscribe Today

New Books

New Series of Focused Books in Print and E-Reader Formats

Design of Experiments“If you’re going to experiment, then it is always worth doing it properly” writes Tom Fearn in this introduction to Design of Experiments.
find out more

Near Infrared Spectroscopy on Agricultural HarvestersThis book provides an overview of the deployment of NIR analysers onto harvesting machinery to give real-time, point-of-cropping data.
find out more

Sample Copy of JNIRS